Customization: | Available |
---|---|
After-sales Service: | Video Technical Support, Online Support |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Work condition
Working Temperature, 0ºC~50ºC. Relative Humidity, 5~95%.
Operation Voltage: 24VDC. MAX range: 22VDC-35VDC.
The THC should be installed in a cab which can provide protection from powder.
The THC should be better used in the situation without high electromagnetic radiation.
Work voltage | Rated DC 24V |
Lifting motor | DC 24V |
Motor drive | PWM |
Output current | 0A-3A |
Load capacity | 100W |
Working temperature | 0 ~50 . ºC ºC |
IHS | proximity switch of IHS |
Voltage divide ratio | 100:1 |
The precision of arc voltage sampling | 0.2V |
The precision of arc voltage adjust | 1V |
The speed of lifting | It determines by highest speed of lifting |
Setting scope of arc voltage | 30V~600V |